一、Application
PR2 Test System is designed and manufactured as one comprehensive type of testing equipment as per API SPEC 6A, GB/T22513, and other related industrial standards, which is capable of carrying out the PR2 level tests for valves, showing as followings: hydrostatic test, gas leakage test, open or operating torque test, open/close cycling dynamic test at room temperature, open/close cycling dynamic gas pressure test at maximum/minimum environmental temperature and valve pressure/temperature cycle testing.
二、System Combination
PR2 test equipment mainly consists of 3 sections, i.e.: Temperature Control System, Torque Control System and PC Control System. Therein, temperature control system is used to create high and low environmental testing temperature; the torque control system is used to control the open/close operations of valves and torque measurement; the PC control system is employed for automatic control of the testing process, acquisition and storage of test data and test reports.
三、Technical Parameters for HPU
1) Maximum Valve Size: Overall Height is 693 mm;
2) Test temperature: -40-200℃;
3) Temperature measurement accuracy: 0.5% F.S;
4) Temperature control accuracy: ± 3 ℃;
5) Environmental chamber internal dimensions: 1440×2650×1450mm(W*D*H)
6) Valve actuator type: stepper motor, reduction gears and torque transducer;
7) Actuator maximum output torque: 1200N.m;
8) Maximum speed: 10 RPM;
9) Dynamic torque measurement range: Max: 1500N.m;
10) Torque measurement accuracy: 0.5% F.S;
11) Control mode: automatic control
12) Power supply:380V, 60Hz
Previous:ESD Control Panel Design and Control Logic
Next article:Wellhead Control Panel for Algeria Project