The ESD control panel controls the opening and closing of four safety valves.
Reference standard
API RP 14C ; API RP 14D; API RP 14F; API RP 550 ; ASTM A269-07
SY/T 6276-1997; GB/T 7932-2003; GB/T 3766-2001; GB/T 14039-2002
Functions & Features
The hydraulic control source for the safety valve actuators is provided by 2 air-driven liquid pumps (pneumatic manual pump operation function). The maximum control pressure of the hydraulic system is 3,000PSI; The driving source is compressed air, and the maximum working pressure of the air pressure circuit is 145PSI.
In case of emergency, the ESD control panel releases the pressure of the actuator after receiving the inductive signal (local ESD switch, remote ESD signal, fusible plug, high/low pressure pilot valve action signal) to close the safety valve.
Reasonable layout,imported brand for the stainless steel high pressure pipeline, beautiful and durable;
The control cabinet is made of 304SS plate, which is rain proof, dust proof and corrosion resistant, and the Ingress Protection reaches IP65.
Technical parameters
Control quantity: One well for 4 safety valves;
Max output pressure: 3000 Psi;
Pneumatic loop pressure: 145 Psi;
Driven power supply: Compressed air;
Test medium: SHELL T15/22
Skid material: Q235, thickness 2.5mm;
Control panel material: 304SS, thickness 2.5mm;
Liquid tank: 40L ,304SS;
Environment temperature: -20℃~+80℃.
For more details,please feel free to contact us.
Previous:Test System for Downhole Tools
Next article:no more