Application
The FIVA valve performance test bench equipment is used for performance testing of FIVA valves, Marine valves, etc., simulating FIVA movement, extreme max position, fail safe mode testing. To conduct the internal leakage testing, signal & flow testing, valve position signal testing, position sensor calibration, etc.
Technical parameters
1) Test Medium: L-HM46 or other hydraulic oil;
2) System rated flow: 70L/min, proportional regulation;
3) Test pressure: 0.7 ~30MPa, proportional adjustment;
4) Cooling circulation oil source: 60L/min, I.SkW;
5) Oil temperature: 42±1℃;
6) Oil tank capacity: 300L, stainless steel;
7) Cooling power : 2lkW;
8) System oil cleanliness: NAS 7 ;
9) Proportional control current: 4-20mA;
10) DC voltage: 0~24VDC;
11) Dimensions of cabinet: custom design, subject to actual design;
12) Test performance: Internal leakage test, signal & flow test, valve position signal test, position sensor calibration, etc for FIVA valve, Marine valve.
13) Functions of data processing system:
a) Real-time collection of data that meets the test requirements, dynamic display of curve graphs, adjustable curve graph frames, local magnification of curves, and equipped with cursor capture function;
b) With functions for data storage, data query, and printing of test reports,etc.;
c) The output report items can be manually entered and selected;
d) Safety protection and alarm prompt functions;
e) It can generate curves included oil temperature, pressure, input signal, position reading signal, input signal-flow rate, etc.
Reference pictures