Wellhead Devices Leak Test System (P/N: A2013)
Standard: · SY/T5053.1~2000 ·SY/T5127 ~ 2002
Application: Wellhead Devices Leak Test System can be used to perform up to 2,100bar leakage test for blowout preventer, christmas tree, choke & kill manifolds and etc.
| ![]() |
Features:
Test media can be compressed air or N2 with a capability of testing on differential pressure levels such as 35Mpa, 140Mpa, 150Mpa, 210MPa
The testing process is fully controlled by PC, all the settings and operations could be fulfilled on the control panel; meanwhile, the remote control allows the operators to manually control all the valves without a real site operation.
Automatic data acquisition supports real-time display of pressure values, time and pressure-time curves. Testing results can be saved and
printed out for further analysis.
All-round monitoring of test process, and the video archive is available.
Dual pressure releasing devices--PC automatic pressure release & manual pressure release, more reliable and safer.
All high pressure valves, tubing and pump made in USA with 316SS to guarantee the test precision and stability.
Electrical control strictly sticking to industry standard with sophisticated industrial control computer and PCI provides more reliable
performance and precise data.
Industrial nitrogen cylinders, nitrogen generator and booster, high pressure air compressor three options for customers to choose.
Model selection:
P/N | Test Pressure | Operation | Test Medium |
A2013-035-A/M-A/N | 35MPa | Manual/Auto | Air/Nitrogen |
A2013-070-A/M-A/N | 70MPa | Manual/Auto | Air/Nitrogen |
A2013-105-A/M-A/N | 105MPa | Manual/Auto | Air/Nitrogen |
A2013-140-A/M-A/N | 140MPa | Manual/Auto | Air/Nitrogen |
A2013-210-A/M-A/N | 210MPa | Manual/Auto | Air/Nitrogen |