Application
The equipment provide the pulse pressure through the hydraulic system,to conduct the pressure fatigue testing by pulse pressure circulating on the specimens.
Technical Parameters
Test medium :65# aviation coolant (provided by end user);
Test pressure: 0 ~ 3MPa (adjustable)
Pressure control accuracy: ±2%FS;
Cycling frequency: 120 times/min (2Hz)
Cycling time:≥100000 adjustable;
Medium temp.:≤60℃,cooling via the cooling-water machine;
Filter precision of cycling system:20μm;
Pressure sensor: 0~4MPa,0.5%F.S.,responses time≤1ms;
Power supply: AC380V 50Hz
Estimated dimensions:800x800x1250mm.
Features &Benefits
Electromagnetic interlock door for safety operation;
Abnormal conditions indication,such as leakage,over-temperature,over-pressure,etc;
304 stainless steel water tank with drain outlet for easy cleanness;
PC with software control,real time display the test data and save the test results automatically for further analysis and print out by end user anytime;
Explosive-proof glass window for easy observation and safety operation.
Reference Picture